Technical specifications
CHANNEL FOR MEASURING WIND PARAMETERS
| Wind speed measuring range, m/s
|
from 0 to 60
|
| Measurement accuracy at wind speed from 0 to 35, m/s
|
±0.3 (or ± 3%)
|
| Measurement accuracy at wind speed from 35 to 60, m/s
|
±5%
|
| Resolution, m/s
|
0,1
|
| Wind direction (azimuth)
|
from 0 to 3600
|
| Measurement accuracy (azimuth)
|
±30
|
| Resolution (azimuth)
|
10
|
CHANNEL FOR MEASURING ATMOSPHERIC PRESSURE
| Pressure measurement range, hPa
|
from 600 to 1100
|
| Measurement accuracy at temperature from 0 to + 30 0С, hPa
|
±0,5
|
| Measurement accuracy at temperature from –50 to + 60 0С, hPa
|
±0,5
|
| Resolution, hPa
|
0,1
|
CHANNEL FOR MEASURING AIR TEMPERATURE
| Temperature measurement range, 0С
|
from –50 to +60
|
| Measurement accuracy, 0С (at + 20 0С)
|
±0,3
|
| Resolution, 0С
|
0,1
|
CHANNEL FOR MEASURING RELATIVE HUMIDITY
| Humidity measurement range, %
|
from 0 to 100
|
| Measurement accuracy from 0 to 90, %
|
±3
|
| Measurement accuracy from 90 to 100, %
|
±5
|
| Resolution, %
|
0,1
|