Technical specifications
CHANNEL FOR MEASURING WIND PARAMETERS
Wind speed measuring range, m/s
|
from 0 to 60
|
Measurement accuracy at wind speed from 0 to 35, m/s
|
±0.3 (or ± 3%)
|
Measurement accuracy at wind speed from 35 to 60, m/s
|
±5%
|
Resolution, m/s
|
0,1
|
Wind direction (azimuth)
|
from 0 to 3600
|
Measurement accuracy (azimuth)
|
±30
|
Resolution (azimuth)
|
10
|
CHANNEL FOR MEASURING ATMOSPHERIC PRESSURE
Pressure measurement range, hPa
|
from 600 to 1100
|
Measurement accuracy at temperature from 0 to + 30 0С, hPa
|
±0,5
|
Measurement accuracy at temperature from –50 to + 60 0С, hPa
|
±0,5
|
Resolution, hPa
|
0,1
|
CHANNEL FOR MEASURING AIR TEMPERATURE
Temperature measurement range, 0С
|
from –50 to +60
|
Measurement accuracy, 0С (at + 20 0С)
|
±0,3
|
Resolution, 0С
|
0,1
|
CHANNEL FOR MEASURING RELATIVE HUMIDITY
Humidity measurement range, %
|
from 0 to 100
|
Measurement accuracy from 0 to 90, %
|
±3
|
Measurement accuracy from 90 to 100, %
|
±5
|
Resolution, %
|
0,1
|