Technical specifications
Frequency range, GHz
|
0,05÷18
|
Maximum range for detection of REA signals if the air object flies at the altitude of 10000 m, km
|
up to 450
|
Information update rate, maximum, s
|
5 |
Sigint envelope by azimuth, deg
|
0÷360
|
Simultaneous scanning band, MHz
|
500; 50; 25; 10; 5
|
Sensitivity of the receiving/direction-finding path, not worse than, dBW:
|
|
• within 500 MHz band, when signal/noise ratio, not more than 10 dB
|
minus 120
|
• within 50 MHz band, when signal/noise ratio, not more than 10 dB
|
minus 130
|
RX dynamic band, not less than, dB
|
70
|
Range of measurement of signal time parameters, μs:
|
|
• pulse duration
|
0,1÷999
|
• pulse repetition period
|
1÷99999
|
DF method in goniometric channel of the radar
|
amplitude
|
DF instrumental accuracy (mean-square error) in goniometric channel, deg
|
3 |
Positioning method used in the Complex
|
multilateration and goniometry
|
Accuracy of signal arrival time measurement, not more than, ns
|
20
|
Potential accuracy of determining the azimuth direction in the TDOA channel, deg
|
0.01
|
Number of tracked targets, not less than
|
200
|
Deployment /folding time, min
|
30
|
Maximum power consumed by station, not more than, kW
|
7
|
Operating temperature range, °С
|
-35 – + 55
|